EN 14399 HSFG Bolts: HR vs HV Systems & Preload Guide

What “friction grip” actually means

High strength friction grip (HSFG) bolting does not work by shear on the bolt shank. It works by clamping: the bolts are tightened to a controlled preload high enough that the friction between the two steel plates carries the entire load. The bolt never bears on the hole wall in normal service, which is why HSFG connections resist fatigue and slip far better than bearing-type bolted joints.

That single difference drives everything else in the standard: the bolts need a declared, tested relationship between torque and preload, the nuts and washers must come from the same system, and the tightening procedure has to be controlled on site. In Europe this is standardised as EN 14399, and buyers specifying “HSFG bolts” for a steel structure in the Gulf, Central Asia or Africa are almost always asking for EN 14399.

The EN 14399 family — and which parts you actually order

Part Title What it covers
EN 14399-1 General requirements System-level rules; the part referenced in the project specification
EN 14399-2 Suitability test for preloading The type test that proves a bolt/nut/washer system reaches preload
EN 14399-3 HR system — hexagon bolt and nut assemblies Large hex head bolts with matching nut and two washers
EN 14399-4 HV system — hexagon bolt and nut assemblies Standard hex head bolts with a dedicated nut and one washer
EN 14399-5 Plain washers Washers for both systems
EN 14399-6 Chamfered plain washers Chamfered variant
EN 14399-8 HV system, fitted bolts HV assemblies with a fitted (close-tolerance) shank
EN 14399-10 HRC system, calibrated wrench Assemblies designed for calibrated-wrench tightening

In practice, EN 14399-3 (HR) and EN 14399-4 (HV) cover about 90% of structural steelwork demand. Always state the part, not just “EN 14399”, on the purchase order — the two systems are not interchangeable.

HR vs HV: the real difference

EN 14399-3 — HR system EN 14399-4 — HV system
Head Large hexagon head (bigger across-flats than ISO 4014) Standard hexagon head, same dimensions as ISO 4014 / ISO 4017
Assembly Bolt + nut + 2 washers Bolt + nut + 1 washer
Nut Large hex nut, height per EN 14399-3 Dedicated nut with tighter tolerances
Why the difference Larger head spreads bearing pressure; two washers protect both faces Standard head for tighter access and to match existing steelwork detailing
Typical use Bridges, heavy structures, wide-flange connections Steel frames where standard head geometry and clearance matter

Because the HV head is a standard ISO 4014 shape, an HV bolt can physically fit a hole designed for an ordinary 8.8 bolt — but the nut and washer are system-specific. Mixing an HV bolt with a DIN 934 nut destroys the preload guarantee, because the torque–tension relationship was never tested for that combination.

Preload values: the number the whole system exists to hit

Size 8.8 — Fp,C (kN) 10.9 — Fp,C (kN)
M12 59 74
M16 88 110
M20 137 172
M24 198 247
M30 314 392

These are the EN 14399-2 preload values that the whole assembly is type-tested against. A structure designed to Eurocode 3 assumes these numbers were actually achieved on site — not estimated from a generic torque chart.

k-class: the part most purchase orders forget

EN 14399-2 defines the torque coefficient (k) in two classes:

  • k1 class: k = 0.10 – 0.16
  • k2 class: k = 0.16 – 0.23

The tightening torque is calculated as M = k × d × Fp,C. If the k-class is not specified, the site cannot calculate a valid torque, and the assembler will typically fall back on a generic bolt torque chart — which will under- or over-tighten the joint. Specify the class on the PO, and require the lot’s torque coefficient test result on the inspection documents.

Three tightening methods used on site

  1. Torque method: apply M = k × d × Fp,C with a calibrated wrench. Simple, but scatter in k means preload scatter of ±30% or worse.
  2. Part-turn (angle) method: torque to a seating value, then rotate a defined angle. More consistent because it works past the yield-independent region.
  3. Direct tension indicator (DTI): compressible washer with protrusions; preload is confirmed by feeler-gauge gap. Common on projects that require documented preload verification.

Whatever method the specification calls for, the bolts must come from a system that was type-tested as an assembly — bolt, nut and washers from the same manufacturer, with the same coating and lubricant state. Re-coating or re-lubricating after delivery invalidates the torque coefficient.

What to check before the containers leave

  • System integrity: bolt, nut and washers from the same EN 14399 system and the same lot; do not accept a mixed-system kit
  • Marking: EN 14399 part number, property class (8.8 / 10.9), manufacturer mark, and lot traceability on the head
  • Torque coefficient test result for the lot, with the k-class stated
  • Hardness and tensile per EN 14399-3/-4, including the nut proof load
  • Coating: hot-dip galvanized assemblies must be tested after coating (EN 14399-10 or project-specific), because galvanising changes the friction behaviour
  • Washer hardness: F436-equivalent hardened washers, not commercial plain washers

These are exactly the fields a 3.1 mill test certificate should carry. For structural steelwork on a project schedule, the documentation package is usually reviewed before the steel is even erected — see our tender and project supply guide for how the submittal timetable works.

HSFG vs ASTM A325 / A490

Both families are friction-type structural bolting, but they are not interchangeable documents:

EN 14399 (HR / HV) ASTM A325 / A490
Region Europe, Middle East, Central Asia, Africa (Eurocode projects) North America, some Gulf specifications written to AISC
Grades 8.8 / 10.9 A325 (medium carbon, 120 ksi) / A490 (alloy, 150 ksi)
Nut pairing System-specific nut, same standard A563 Grade C (A325) / A563 DH or DH3 (A490)
Faying surface Class A / B per EN 1090-2 with slip factor Class A / B per RCSC with slip coefficient

If a project is written to Eurocode, ship EN 14399; if it is written to AISC/RCSC, ship A325/A490. Full grade-by-grade comparison is in our A325 vs A490 structural bolts guide, and the finished product range is on our HSFG structural bolts page.

Frequently asked questions

What does HSFG stand for?
High Strength Friction Grip — a bolted connection where the plates are clamped so tightly that friction, not bolt shear, carries the load. In Europe the governing standard is EN 14399.

What is the difference between EN 14399-3 and EN 14399-4?
EN 14399-3 is the HR system: large hex head bolts with a matching nut and two washers. EN 14399-4 is the HV system: standard ISO 4014-shape hex bolts with a dedicated nut and one washer. Both reach the same preload values but the assemblies are not interchangeable.

Can I use ordinary 8.8 bolts for a friction grip connection?
No. Ordinary 8.8 bolts are not type-tested for preload, are not supplied with system-matched nuts and washers, and their torque coefficient is not declared. Use EN 14399 assemblies.

What torque should be used for M20 10.9 HSFG bolts?
Torque depends on the k-class: M = k × d × Fp,C. With Fp,C = 172 kN for M20 10.9 and k = 0.13, the torque is about 447 Nm. Never use a generic torque chart for HSFG assemblies.

Are galvanized HSFG bolts available?
Yes, hot-dip galvanized EN 14399 assemblies are supplied to EN 14399-10 or project-specific requirements. Because galvanising changes friction behaviour, the torque coefficient must be re-established for the coated lot.

ShareWhatsAppLinkedInEmail
Wholesale · Bulk · Tender & Project Supply

Full-Range Fasteners for Wholesalers, Importers, EPC Contractors & Tender Buyers

Ready stock and bulk supply for wholesalers, importers, distributors, building-material merchants, EPC contractors and tender buyers. We quote by the tonne and by the full container, and we supply the documentation package that tender submissions require — MTC, CO, third-party inspection and a signed delivery commitment.

  • Ready stock · full-range fasteners held in stock for fast dispatch
  • Bulk & container pricing · tonne and 20GP / 40HQ quantities with dealer, distributor, importer and stockist tiers
  • Tender & project supply · EN 10204 3.1 MTC, CO, third-party inspection (SGS / BV), HS codes and delivery commitment for bid documents
  • Resale packing & private label · your brand, barcode and cartons
  • Merchant terms · T/T payment, FOB / CIF / DAP, 15-25 day lead time, staged delivery per construction schedule

Bulk and project quantities supplied worldwide — wholesalers, importers, distributors, EPC contractors and tender buyers.

Stay in touch